Среда, 3 февраля 2016 года
back
Perio iQ
Volume 26, 2015
page 138-151

Secondary stabilization of maxillary M-4 treatment with unstable implants for immediate function: biomechanical considerations and report of 10 cases after 1 year in function

  • Ole T. Jensen,

    DDS, MS
    Oral Surgeon, Private Practice, Denver, Colorado.

    more by this author
  • Michael A. Pikos

    DDS
    Private Practice Limited to Oral and Maxillofacial Surgery, Denver, Colorado, USA.

    more by this author
  • Purpose: Primary stability of dental implants, particularly when they are placed into immediate function in the maxilla, has been thought to be required. An alternative to primary stability is secondary stabilization, which can be obtained by a four-implant distribution pattern using 30-degree angulations for all four implants in the so-called “M-4” treatment scheme in combination with cross-arch stabilization from a prosthesis. If successful, the use of these two measures brings into question whether or not primary stability is required for immediate function in the maxilla.

    Materials and Methods: Patients were treated with the M-4 implant scheme with immediate function, despite the instability of at least one of the four implants. Instability was defined as less than 15 Ncm of insertion torque and palpable mobility, and an average anteroposterior spread of 15 mm between each implant was sought. The patients were followed for 1 year.

    Results: Ten patients were treated with a total of 40 implants. Composite insertion torque of the four implants was less than 100 Ncm in half of the patients; the average anteroposterior spread was 15.6 mm. After 1 year, no implants had been lost, and bone levels around all implants were at or near operative levels. There were no failures of provisional or definitive prostheses.

    Conclusions: M-4 distribution of implants with an average of 15 mm of anteroposterior spread and cross-arch stabilization did not require that all four implants had high insertion torque; in fact, all mobile implants stabilized and osseointegrated under these conditions.

    Key words:
    All-on-Four
    anteroposterior spread
    composite insertion torque
    cross-arch stabilization
    immediate function maxilla
    insertion torque
    M-4
    primary stability
    secondary stabilization.
    All-on-Four
    anteroposterior spread
    composite insertion torque
    cross-arch stabilization
    immediate function maxilla
    insertion torque
    M-4
    primary stability
    secondary stabilization.
    Original publication:
    Int J Oral Maxillofac Implants 2014;29:e232–e240. doi: 10.11607/jomi.te59